US customary units
| Pressure | 3000 psi |
|---|---|
| Flow rate | 10 gpm |
| Overall pump efficiency | 85 % |
| Fluid power | 17.5 hp |
| Shaft power required | 20.59 hp |
| Heat from losses | 3.088 hp |
Free calculator · Hydraulics
Fluid power from pressure and flow, and the shaft power a pump needs at a given efficiency, in hp or kW.
Result
For preliminary engineering and field checks. Verify against your project specification before you rely on it.
The app
LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.
P fluid = p · Q
hp = psi × gpm / 1714
kW = bar × L/min / 600
P shaft = P fluid / η
Hydraulic power is pressure times flow. The constants 1714 and 600 only take care of the units. Dividing by the pump's overall efficiency gives the power the motor or engine has to supply at the shaft.
The difference between shaft power and fluid power ends up as heat in the oil.
The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.
| Pressure | 3000 psi |
|---|---|
| Flow rate | 10 gpm |
| Overall pump efficiency | 85 % |
| Fluid power | 17.5 hp |
| Shaft power required | 20.59 hp |
| Heat from losses | 3.088 hp |
| Pressure | 200 bar |
|---|---|
| Flow rate | 40 L/min |
| Overall pump efficiency | 85 % |
| Fluid power | 13.33 kW |
| Shaft power required | 15.69 kW |
| Heat from losses | 2.353 kW |
One horsepower is 33,000 ft·lbf per minute and one US gallon is 231 cubic inches. 33,000 × 12 ÷ 231 = 1,714, which converts psi × gpm into horsepower.
With no pump data, 85% overall is a common planning figure for a hydraulic pump in good condition. Gear pumps tend to run lower and piston pumps higher. Replace the assumption with manufacturer data before you select a motor.
Everything that does not leave the system as useful work. At a minimum, the pump's losses heat the oil. In a system that throttles or relieves flow, a much larger share does, and that heat load is what the cooler and reservoir have to remove.
The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.
Start a Conversation