0%

Free calculator · Pumps

Pump Affinity Laws Calculator

See how flow, head and power change when a centrifugal pump runs at a different speed.

Units
rpm
rpm
gpm
ft
hp

Result

Flow at new speed
414.3 gpm94.09 m³/h
Head at new speed
82.38 ft25.11 m
Power at new speed
11.38 hp8.484 kW
Speed ratio
0.8286

For preliminary engineering and field checks. Verify against your project specification before you rely on it.

The app

Take the full set to the plant floor.

LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.

Coming soon on the Apple App StoreGet it on Google Play
See what is in the app

How it is calculated

Q₂ = Q₁ · (N₂ / N₁)

H₂ = H₁ · (N₂ / N₁)²

P₂ = P₁ · (N₂ / N₁)³

Q
flow
H
head
P
shaft power
N
rotational speed

For a centrifugal pump with the same impeller, flow follows speed, head follows speed squared and power follows speed cubed. The laws move each point on the pump curve to a matching point on the curve for the new speed, at about the same efficiency.

The cube law is why variable-speed drives save energy: at 80% speed the pump draws roughly half the power.

Before you rely on it

  • The laws move the pump curve, not the operating point. The pump runs where its new curve crosses the system curve. With significant static head, flow falls faster than speed and the power saving is smaller than the cube law suggests.
  • They apply to centrifugal pumps. Gear, screw, vane and piston pumps deliver flow roughly in proportion to speed while the system sets the pressure.
  • Accuracy is best for modest speed changes, because efficiency shifts at large reductions.
  • Check NPSH and the pump's minimum flow at the new speed.

Worked example

The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.

US customary units

Original speed1750 rpm
New speed1450 rpm
Flow at original speed500 gpm
Head at original speed120 ft
Power at original speed20 hp
Flow at new speed414.3 gpm
Head at new speed82.38 ft
Power at new speed11.38 hp
Speed ratio0.8286

SI metric units

Original speed1450 rpm
New speed1200 rpm
Flow at original speed120 m³/h
Head at original speed40 m
Power at original speed18 kW
Flow at new speed99.31 m³/h
Head at new speed27.4 m
Power at new speed10.2 kW
Speed ratio0.8276

Questions about this calculator

01Do the affinity laws work for gear and screw pumps?

Not in this form. A positive-displacement pump delivers flow roughly in proportion to speed, and its discharge pressure is set by the system it pumps into. Power then follows flow times pressure, not the cube of speed.

02How much power do I save by slowing the pump?

On a friction-dominated system with little static head, power falls with the cube of speed: 90% speed needs about 73% of the power and 80% speed about 51%. Static head reduces the saving.

03Can I use this for a different impeller diameter?

For a small trim of the same impeller, the same three relationships are commonly used with the diameter ratio in place of the speed ratio. It is an approximation. The manufacturer's curve for the trimmed impeller is the reliable source.

Professional-use note

The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.

Start a Conversation

Bring the system requirements. We will bring focused engineering support.

Discuss Your System

Quick answers

Search Spartan’s engineering services, free web calculators, LubeCalc Pro, and the rest of the website.

Open sitemap