0%

Free calculator · Oil viscosity

Viscosity-Temperature Calculator (ASTM D341)

Estimate an oil's kinematic viscosity at any temperature from two known points, such as the 40 °C and 100 °C values on its data sheet.

Units
°F
cSt

From the oil's data sheet.

°F
cSt
°F

Result

Kinematic viscosity
20.62 cSt
Constant A
9.418
Constant B
3.6844

For preliminary engineering and field checks. Verify against your project specification before you rely on it.

The app

Take the full set to the plant floor.

LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.

Coming soon on the Apple App StoreGet it on Google Play
See what is in the app

How it is calculated

log₁₀ log₁₀ (ν + 0.7) = A − B · log₁₀ T

ν
kinematic viscosity in cSt
T
absolute temperature in kelvin
A, B
constants for the oil, found from the two known points

This is the relation behind the ASTM D341 viscosity-temperature chart. For most petroleum oils, plotting log log (ν + 0.7) against log T gives a straight line, so two measured points fix the line and any other temperature can be read from it.

The calculator solves A and B from your two points and evaluates the line at the temperature you ask for.

Before you rely on it

  • Interpolating between the two known temperatures is the reliable use. Extrapolating beyond them is less certain, most of all at low temperatures near the pour point, where wax begins to affect flow.
  • The 0.7 constant holds for viscosities of about 2 cSt and above. The calculator refuses known points below that.
  • The method suits mineral oils and similar hydrocarbon fluids. Water-glycol and other non-hydrocarbon fluids may not follow the same line, so use the supplier's curve for those.
  • Oil in service drifts from its data sheet. When the margin is tight, use measured viscosities from an oil analysis report.

Worked example

The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.

US customary units

First known temperature104 °F
Viscosity at first temperature46 cSt
Second known temperature212 °F
Viscosity at second temperature6.8 cSt
Temperature of interest140 °F
Kinematic viscosity20.62 cSt
Constant A9.418
Constant B3.6844

SI metric units

First known temperature40 °C
Viscosity at first temperature46 cSt
Second known temperature100 °C
Viscosity at second temperature6.8 cSt
Temperature of interest60 °C
Kinematic viscosity20.62 cSt
Constant A9.418
Constant B3.6844

Questions about this calculator

01Where do I find two viscosity points for my oil?

The product data sheet almost always lists kinematic viscosity at 40 °C and 100 °C. An oil analysis report gives measured values for the oil that is actually in the machine.

02Can I use this with ISO VG grades?

Yes. The ISO viscosity grade number is the midpoint viscosity in cSt at 40 °C, so an ISO VG 46 oil is close to 46 cSt at 40 °C. You still need a second point, normally the 100 °C value from the data sheet, because that depends on the oil's viscosity index.

03How accurate is the result?

Between the two known temperatures it normally agrees closely with measured values for mineral oils. Accuracy falls off the further you extrapolate, so treat cold-start estimates as a guide and confirm them with supplier data when the margin is tight.

Professional-use note

The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.

Start a Conversation

Bring the system requirements. We will bring focused engineering support.

Discuss Your System

Quick answers

Search Spartan’s engineering services, free web calculators, LubeCalc Pro, and the rest of the website.

Open sitemap

Search runs in this browser. You can choose to share a submitted search after its result.