US customary units
| Pipe size | NPS 2 Sch 40 (52.5 mm, 2.067 in) |
|---|---|
| Flow rate | 40 gpm |
| Kinematic viscosity | 32 cSt |
| Velocity | 3.825 ft/s |
| Reynolds number | 1,913 |
| Flow regime | Laminar |
| Inside diameter | 2.067 in |
| Flow area | 3.355 in² |
Free calculator · Piping and flow
Flow velocity and Reynolds number for oil or water in standard steel pipe. Pick a pipe size or enter your own inside diameter.
Result
For preliminary engineering and field checks. Verify against your project specification before you rely on it.
The app
LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.
v = Q / A
A = π · D² / 4
Re = v · D / ν
Velocity is flow divided by the open area of the pipe. The Reynolds number then compares that velocity and diameter with the fluid's viscosity to tell you how the flow behaves.
Two shortcuts give the same answer by hand: v (ft/s) = 0.4085 × gpm ÷ d², with d in inches, and v (m/s) = 21.22 × L/min ÷ d², with d in millimetres.
Below a Reynolds number of about 2,300 the flow is laminar. Above about 4,000 it is turbulent. In between it can switch back and forth.
The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.
| Pipe size | NPS 2 Sch 40 (52.5 mm, 2.067 in) |
|---|---|
| Flow rate | 40 gpm |
| Kinematic viscosity | 32 cSt |
| Velocity | 3.825 ft/s |
| Reynolds number | 1,913 |
| Flow regime | Laminar |
| Inside diameter | 2.067 in |
| Flow area | 3.355 in² |
| Pipe size | NPS 2 Sch 40 (52.5 mm, 2.067 in) |
|---|---|
| Flow rate | 150 L/min |
| Kinematic viscosity | 32 cSt |
| Velocity | 1.155 m/s |
| Reynolds number | 1,895 |
| Flow regime | Laminar |
| Inside diameter | 52.5 mm |
| Flow area | 21.65 cm² |
It depends on what the line does and on the governing specification. Suction and gravity drain lines run slowly so the pump stays fed and drains do not back up. Pressure lines can run faster. Start from the limit in your project specification, then use this calculator to check each line size against it.
It tells you whether flow is laminar or turbulent, and pressure drop is calculated differently for each. Oil lines are often laminar, especially at cold start, and in laminar flow the pressure drop rises in direct proportion to viscosity.
The actual inside diameter. Tube is sold by outside diameter and wall thickness, so the inside diameter is the outside diameter minus twice the wall. Hose is sold by nominal bore. Choose the custom inside diameter option and enter that value.
The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.