0%

Free calculator · Pumps

NPSH Available Calculator

Net positive suction head available at the pump inlet, from surface pressure, vapor pressure, static head and suction-line losses, with an optional check against NPSH required.

Units
psia

Atmospheric pressure at sea level is 14.7 psia (101.3 kPa). Use the vessel pressure for a closed tank.

psia

Absolute. Water at 68 °F (20 °C) is 0.34 psia (2.34 kPa). Mineral lube oils are usually close to zero.

lb/ft³
ft

Liquid level above the pump centreline is positive. Use a negative value for a suction lift.

ft

In head of the pumped liquid, at the flow you are checking.

ft

From the pump curve at the same flow.

Result

NPSH available
41.19 ft12.56 m
Surface pressure head
33.98 ft10.36 m
Vapor pressure head
0.7859 ft0.2395 m

For preliminary engineering and field checks. Verify against your project specification before you rely on it.

The app

Take the full set to the plant floor.

LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.

Coming soon on the Apple App StoreGet it on Google Play
See what is in the app

How it is calculated

NPSHa = (P surface − P vapor) / (ρ · g) + h static − h friction

P surface
absolute pressure on the liquid surface
P vapor
vapor pressure of the liquid at pumping temperature
ρ
liquid density
h static
liquid level above the pump centreline (negative for a lift)
h friction
head loss in the suction line

NPSH available is the absolute head at the pump suction above the liquid's vapor pressure. Pressure on the liquid surface pushes liquid toward the pump. Vapor pressure, a suction lift and suction-line friction all take away from it.

Every term is expressed as head of the pumped liquid. Static head is positive when the liquid level is above the pump centreline, which is a flooded suction, and negative for a lift.

Before you rely on it

  • The NPSH required shown on a pump curve is normally the point where head has already dropped by 3% because of cavitation. Running with available equal to required means the pump is already cavitating, so a margin is needed. Your specification or the pump vendor sets how much.
  • Use the worst case: lowest liquid level, highest pumping temperature and highest flow.
  • For viscous oil, suction-line friction usually decides the result. Calculate it with the cold-start viscosity.
  • Atmospheric pressure falls with altitude, to about 12.2 psia (84 kPa) at 5,000 ft (1,500 m).
  • Entrained air and dissolved gas are outside this calculation, and they matter in lube oil reservoirs.

Worked example

The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.

US customary units

Absolute pressure on the liquid surface14.7 psia
Vapor pressure at pumping temperature0.34 psia
Liquid density62.3 lb/ft³
Static head10 ft
Suction line friction loss2 ft
NPSH available41.19 ft
Surface pressure head33.98 ft
Vapor pressure head0.7859 ft

SI metric units

Absolute pressure on the liquid surface101.3 kPa abs
Vapor pressure at pumping temperature2.34 kPa abs
Liquid density998 kg/m³
Static head3 m
Suction line friction loss0.6 m
NPSH available12.51 m
Surface pressure head10.35 m
Vapor pressure head0.2391 m

Questions about this calculator

01What is the difference between NPSHa and NPSHr?

NPSH available describes your system: what the suction side delivers to the pump. NPSH required describes the pump at a given flow and speed, and comes from the manufacturer's curve. The system has to supply more than the pump requires.

02What vapor pressure should I use for lube oil?

Mineral lube oils have very low vapor pressure at normal operating temperatures, so that term is usually close to zero and suction-line friction dominates. Use the supplier's value if one is published. For water and light hydrocarbons the vapor pressure is significant and must come from property tables at the pumping temperature.

03Does NPSH apply to positive-displacement pumps?

Yes. The idea is the same, although makers of gear and screw pumps often state it as a minimum inlet pressure, or net positive inlet pressure, instead of a head.

Professional-use note

The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.

Start a Conversation

Bring the system requirements. We will bring focused engineering support.

Discuss Your System

Quick answers

Search Spartan’s engineering services, free web calculators, LubeCalc Pro, and the rest of the website.

Open sitemap

Search runs in this browser. You can choose to share a submitted search after its result.