0%

Free calculator · Piping and flow

Orifice Flow Calculator

Liquid flow through a sharp-edged orifice plate, from bore, pipe size, differential pressure and density.

Units
in
in
psi
lb/ft³

About 0.60 to 0.62 for a sharp-edged plate in turbulent flow.

Result

Flow rate
59.19 gpm224 L/min
Beta ratio (d/D)
0.484
Velocity through the orifice
24.18 ft/s7.369 m/s

For preliminary engineering and field checks. Verify against your project specification before you rely on it.

The app

Take the full set to the plant floor.

LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.

Coming soon on the Apple App StoreGet it on Google Play
See what is in the app

How it is calculated

Q = Cd · A · √(2 · ΔP / ρ) / √(1 − β⁴)

A = π · d² / 4

β = d / D

Q
volumetric flow
Cd
discharge coefficient
A
orifice area
d
orifice diameter
D
pipe inside diameter
ΔP
differential pressure across the plate
ρ
liquid density

Flow through an orifice comes from Bernoulli's equation between the pipe and the jet, corrected by a discharge coefficient for the contraction of the jet and for friction. The 1/√(1 − β⁴) term accounts for the velocity the liquid already has in the upstream pipe.

A thin, sharp-edged plate in fully turbulent flow has a discharge coefficient close to 0.6. A value of 0.61 is a common starting point.

Before you rely on it

  • The discharge coefficient depends on Reynolds number, beta ratio and where the pressure taps are. For metering accuracy, take the coefficient from ISO 5167 or the equivalent standard.
  • Viscous oil at low Reynolds number does not behave like the turbulent case, and a fixed 0.61 can be well off.
  • The differential pressure is the drop measured across the plate. The permanent pressure loss further downstream is smaller, because some pressure recovers.
  • Thick plates, rounded edges and drilled restriction plugs have different coefficients.
  • This is for liquids. Gases need an expansibility factor.

Worked example

The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.

US customary units

Orifice diameter1 in
Pipe inside diameter2.067 in
Differential pressure10 psi
Liquid density62.4 lb/ft³
Discharge coefficient (Cd)0.61
Flow rate59.19 gpm
Beta ratio (d/D)0.484
Velocity through the orifice24.18 ft/s

SI metric units

Orifice diameter25 mm
Pipe inside diameter52.5 mm
Differential pressure0.7 bar
Liquid density998 kg/m³
Discharge coefficient (Cd)0.61
Flow rate218.5 L/min
Beta ratio (d/D)0.476
Velocity through the orifice7.418 m/s

Questions about this calculator

01What discharge coefficient should I use?

About 0.60 to 0.62 for a thin, sharp-edged plate in turbulent flow. Rounded or chamfered inlets are higher, and a well-rounded nozzle approaches 0.98.

02How do I size a restriction orifice for a target flow?

Enter a trial bore and adjust it until the flow matches your target at the available differential pressure. Flow rises roughly with the square of the bore, so a small change in diameter has a large effect.

03Why does my result differ from a metering standard?

Standards such as ISO 5167 calculate the discharge coefficient from Reynolds number, beta ratio and tapping arrangement instead of assuming a fixed value. The difference is small in fully turbulent flow and can be much larger in viscous flow.

Professional-use note

The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.

Start a Conversation

Bring the system requirements. We will bring focused engineering support.

Discuss Your System

Quick answers

Search Spartan’s engineering services, free web calculators, LubeCalc Pro, and the rest of the website.

Open sitemap

Search runs in this browser. You can choose to share a submitted search after its result.