US customary units
| Flow rate | 100 gpm |
|---|---|
| Inlet pressure | 100 psi |
| Outlet pressure | 96 psi |
| Specific gravity | 1 |
| Required Cv | 50 |
| Equivalent Kv | 43.25 |
| Pressure drop | 4 psi |
Free calculator · Piping and flow
Required flow coefficient for a valve in liquid service, from flow rate, pressure drop and specific gravity, with the equivalent Kv.
Result
This is the basic sizing equation. It does not check for flashing, cavitation or choked flow, and it applies no viscosity correction.
For preliminary engineering and field checks. Verify against your project specification before you rely on it.
The app
LubeCalc Pro has 47 engineering calculators and 18 reference resources that work offline, with saved projects and PDF reports.
Cv = Q · √(SG / ΔP)
Kv = 0.865 · Cv
Cv is defined as the flow of water at 60 °F, in US gallons per minute, that passes through a valve with a pressure drop of 1 psi. The sizing equation scales that definition to your flow, pressure drop and liquid density.
Kv is the metric equivalent: cubic metres per hour of water at a pressure drop of 1 bar.
The built-in example in each unit system, so you can check a hand calculation against the calculator. Reset example loads the same inputs.
| Flow rate | 100 gpm |
|---|---|
| Inlet pressure | 100 psi |
| Outlet pressure | 96 psi |
| Specific gravity | 1 |
| Required Cv | 50 |
| Equivalent Kv | 43.25 |
| Pressure drop | 4 psi |
| Flow rate | 22.7 m³/h |
|---|---|
| Inlet pressure | 7 bar |
| Outlet pressure | 6.72 bar |
| Specific gravity | 1 |
| Required Cv | 49.6 |
| Equivalent Kv | 42.9 |
| Pressure drop | 0.28 bar |
Multiply Cv by 0.865 to get Kv, or multiply Kv by 1.156 to get Cv.
No. Compressible flow needs an expansion factor and has its own choked-flow limit. This calculator is for liquids only.
A little. Required Cv scales with the square root of specific gravity, so oil at 0.87 needs about 7% less Cv than water for the same flow and pressure drop. Viscosity usually matters more.
The formula on this page is tested against published reference values or a written-out hand calculation. The result supports preliminary engineering and field checks. It does not replace detailed engineering analysis, the applicable project standards or professional judgment.